RE: Inch-Diameter conversion to weights and lengths

So are you the purchasing guy and are trying to estimate shipping cost? ...Well if your really interested in getting "weights" then I suggest gettin...

12 years ago
Reply
RE: Pump Piping

"IF" the pump suction and discharge are either 125# or 250# the pump is cast iron, and whether it's listed or not, the pump nozzles are "flat faced"! ...

12 years ago
Reply
RE: all fellow pipers, Could you pls let me know why the fence is required to be kept all around the pig trap facility?

This was a waste water pipeline, the pigging operation was for cleaning & smart pigging (once a year) only, and why would you want to do that at n...

12 years ago
Forum
Reply
RE: all fellow pipers, Could you pls let me know why the fence is required to be kept all around the pig trap facility?

This was a waste water pipeline, the pigging operation was for cleaning & smart pigging (once a year) only, and why would you want to do that at n...

12 years ago
Forum
Reply
RE: Would it be possible to weld a 2" olet onto the back of an 8" equal tee and calling it a special item?

swallace99 ..."Generally this sort of configuration is not allowed under most codes as it would invalidate the warranty of the fitting and you coul...

12 years ago
Forum
Reply
RE: Would it be possible to weld a 2" olet onto the back of an 8" equal tee and calling it a special item?

swallace99 ..."Generally this sort of configuration is not allowed under most codes as it would invalidate the warranty of the fitting and you coul...

12 years ago
Forum
Reply
RE: I am setting up cadworx specs and we have gotten into a discussion on the flange thickness dimension of FF vs RF

I believe all steel flanges start out as raise-face connections, I'd hazard to guess manufactures sell 50/100 flanges before they'd need a single flat...

12 years ago
Forum
Reply
RE: I am setting up cadworx specs and we have gotten into a discussion on the flange thickness dimension of FF vs RF

I believe all steel flanges start out as raise-face connections, I'd hazard to guess manufactures sell 50/100 flanges before they'd need a single flat...

12 years ago
Forum
Reply
RE: Would it be possible to weld a 2" olet onto the back of an 8" equal tee and calling it a special item?

I've seen connections like this all the time, It's basically dictated by piping configuration limitations. I don't see a need to call it a specialty i...

12 years ago
Forum
Reply
RE: Would it be possible to weld a 2" olet onto the back of an 8" equal tee and calling it a special item?

I've seen connections like this all the time, It's basically dictated by piping configuration limitations. I don't see a need to call it a specialty i...

12 years ago
Forum
Reply
RE: Can you please educate me and help me to understand: What is the connection between P&ID, Line Lists & Isometrics?

Just poking fun, anybody in this business as long as we have, it's the one thing that makes the job tolerable at times, hope I didn't hurt your feelin...

12 years ago