Reply
RE: A/G pipe to U/G interface-cathodic protection

Yes, that is right. These are known as isolating flanges. Piping which are buried in soil ;have to be given a positive current to nullify the corros...

8 years ago
Reply
RE: Underground Steam line

Function Perhaps this is a line with waste steam (that has completed its duty) with considerable condensate and has to be drained out. In such a ca...

8 years ago
Forum
Reply
RE: What is High point vent and Low point drain…..?

talking about hydrotesting, I have a few questions: A) which of the fluid service and pipe sizes are to be hydrotested? B) Which of the fluid se...

18 years ago
Reply
RE: I am new to this forum. Can anyone please explain to me: A) What is the purpose of pipe rack?

Jop, Thanks a lot for your crystal clear clarification. I have one more query: In some of the plants there are a combination of both pipe racks...

18 years ago