Branch Reinforcement
How this calculation works: Branch Reinforcement — Companion Article
Branch reinforcement
Preliminary. This result needs engineering review before anyone uses it. It is one welded branch under internal pressure. It is not an extruded outlet, and it does not check a second opening nearby.
Formula
t = P × D / (2 × (S × E × W + P × Y))
d1 = (Db − 2 × (Tb × (1 − mill) − c)) / sin β
A1 = th × d1 × (2 − sin β)
d2 = the greater of d1 and (Tb net + Th net + d1 / 2), and not more than Dh
A2 = (2 × d2 − d1) × (Th net − th)
L4 = the smaller of 2.5 × Th net and 2.5 × Tb net + Tr
A3 = 2 × L4 × (Tb net − tb) / sin β × the branch stress ratio
A4 = 2 × pad width inside the zone × (Tr − c) × the pad stress ratio
Equation (3a) gives th for the header and tb for the branch. You enter S, E, W and Y. A blank branch S, E, W or Y uses the header value. Mill undertolerance reduces both nominal walls before c is subtracted. Th net and Tb net are those remainders. β is the smaller angle between the branch axis and the header axis.
The connection passes when A2 + A3 + A4 is at least A1. A4 is the pad only. Fillet welds are not included. The stress ratio is the allowable stress of that part divided by the header allowable stress, and it is not taken above 1. Leave the pad blank to size one when the pipes alone are short. The trial pad thickness is then the header wall after mill and c.
W starts at 1.0. Y starts at 0.4. The mill field starts at 12.5%. Those are starting values, not a completed material specification. Check them.
Check this tool
Branch Reinforcement version 1.0.0
This records your check of the tool output. It does not change the tool or the engineering data.